[dm-devel] multipath with dual Compaq SA462 connected to MSA500
Andreas Huck
dm-devel at huck.it
Tue Oct 10 10:21:13 UTC 2006
Hi,
I'd like to enable some sort of multipath to a RAID device which
is connected by two Smart Array 462 to a MSA500. The host is a DL380 G4.
In contrast to MSA1000 the MSA500 is just directly attached, no HBA
involved.
The RAID appears as /dev/cciss/c1d0 and /dev/cciss/c2d0 and currently
I am forced to disable one path by lvm filter.
Without the lvm filter I get:
Found duplicate PV iXZqRZZg8X6pNn4RBrxRbFiK8O6txY0b: using
/dev/cciss/c2d0p1 not /dev/cciss/c1d0p1
So, I'd like to use both controllers but setup multipath on them. Anyone
around who succeeded with such a setup? It should work since HP offers
some Win*** driver for it, but I need to enable it with SLES9-SP3++ ;-)
The drives do not register as scis defices and to not appear in
/proc/scsi/scsi. Therefore, /sbin/scsi_id -g -u -s /block/%n
does not work of course.
# multipath -v2 -d
dm names N
dm table vgdata-netview N
dm table vglocal-tivoli N
dm table vgdata-oradata N
dm table vglocal-tmp N
dm table vglocal-optoracle N
dm table vgdata-etc_tivoli N
dm table vglocal-var N
So just the LVM devices appear, vgdata is on the MSA500.
Any hints apprecciated!
Thanks and best regards,
Andreas Huck
More information about the dm-devel
mailing list