[Date Prev][Date Next] [Thread Prev][Thread Next]
[Thread Index]
[Date Index]
[Author Index]
Re: [Linux-cluster] Rhcs4 fence with no hardware power switch
- From: Lon Hohberger <lhh redhat com>
- To: linux clustering <linux-cluster redhat com>
- Subject: Re: [Linux-cluster] Rhcs4 fence with no hardware power switch
- Date: Mon, 29 Aug 2005 15:22:05 -0400
On Mon, 2005-08-29 at 02:26 +0000, nattapon viroonsri wrote:
> I use RedHat cluster v4 for HA and have no power switch hardware
> When i disconnected network cable for client access resource , Failover
> have occur as expect
> But the server that was disconnect network cable not be rebooted or fenced
> like rhcs V3(even no power switch). And the failed server can't not join
> cluster again.
Eep, no failover should have occurred if you don't have fencing.
> In Rhcs V3. it reboot fail node automatically without hardware power switch
>
> So, Have anyway to reboot failed node(network problem or server problem)
> without use hardware power switch to make failnode to clean state again ?
You need fencing hardware with RHCS4/RHEL4. I'd check ebay if you're
not looking to spend a lot, you can get a WTI NPS115 for pretty cheap
nowadays (under $100!).
You can run with manual fencing, but no automatic recovery will occur,
and this isn't a supported solution.
-- Lon
[Date Prev][Date Next] [Thread Prev][Thread Next]
[Thread Index]
[Date Index]
[Author Index]