[linux-lvm] vgimport problem
Heinz J . Mauelshagen
mauelshagen at sistina.com
Wed Feb 26 19:18:01 UTC 2003
We fixed a vgimport bug with out-of-sequence PV numbers in LVM 1.0.6.
If pvdata shows you, that your PVs are not sequentially numbered (i.e. 1,3,4), you probably want to try 1.0.6.
Regards,
Heinz -- The LVM Guy --
On Wed, Feb 26, 2003 at 06:54:43PM +0100, Dieter Stueken wrote:
> sorry, I just got the next problem, hopefully not that stupid again :-)
>
> I exported a VG of three PV's last week.
> When I now try to import them again, I get:
>
> -> vgimport data3 /dev/hdc /dev/hdd2 /dev/hdb
> vgimport -- ERROR: wrong number of physical volumes to import volume
> group "data3"
>
> I looked into each PV by pvdata and everything seems OK.
> The UUIDs are OK and there are exactly 3 ones listed.
> I can't get any hint about any missing PV. Running vgimport -v
> does not report any additional errors, too.
>
> any advice?
>
> Dieter.
> --
> Dieter Stüken, con terra GmbH, Münster
> stueken at conterra.de
> http://www.conterra.de/
> (0)251-7474-501
>
>
> _______________________________________________
> linux-lvm mailing list
> linux-lvm at sistina.com
> http://lists.sistina.com/mailman/listinfo/linux-lvm
> read the LVM HOW-TO at http://tldp.org/HOWTO/LVM-HOWTO/
*** Software bugs are stupid.
Nevertheless it needs not so stupid people to solve them ***
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Heinz Mauelshagen Sistina Software Inc.
Senior Consultant/Developer Am Sonnenhang 11
56242 Marienrachdorf
Germany
Mauelshagen at Sistina.com +49 2626 141200
FAX 924446
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
More information about the linux-lvm
mailing list