[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]

Re: [linux-lvm] vgs result code error



On 2009-07-21 05:35, Alasdair G Kergon wrote:
On Tue, Jul 21, 2009 at 04:41:46AM -0500, Ron Johnson wrote:
Debian Sid's 2.02.44-3 returns a non-zero code, so either RH fixed it upstream, or Debian patched it...

# vgs /dev/sdc1
  WARNING: Ignoring duplicate config node: filter (seeking filter)
  Volume group "sdc1" not found
# echo $?
5

That's a *different* error case that works correctly.

Yes, I agree that the original case mentioned should give EINVALID_CMD_LINE
instead of ECMD_PROCESSED.


> On 2009-07-21 02:16, Masanari Iida wrote:
> # vgs /dev/cciss/c0d3p3
>   Invalid volume group name: cciss/c0d3p3

Hey, you're right!!

But why?  (I tried to mimic his example as best I could.)

Is it because of the multi-level device name, and the parser getting confused?

--
Scooty Puff, Sr
The Doom-Bringer


[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]