On Fri, 2004-06-25 at 09:56 +0100, David Barker wrote:
> Many thanks - the WTI-230 look's good, so I'll probably start hunting
> that :D
>
> Out of curiosity, the gui-interface accepts two power-controler's per
> member. Is this in cases where two seperate controler's are used for the
> same host (and both are killed at the same time in the case of a failed
> node?) Or is it something for bugzilla? :-)
Actually it accepts an unlimited number, I think. However, clumanager
won't use anything beyond the first 3. ;)
Many switches don't allow the toggling of power switch ports by user-
defined name.
For switches in this category, you'd have to specify the same switch
twice (with two different ports). While inelegant, the procedure is the
same for the same switch with two different ports, two different user
names on the same switch, or two (or three) entirely different switches.
This is in contrast with RHEL 2.1's behavior, which only accepted one
power switch.
-- Lon