Appendix B. Fence Device Parameters
This appendix provides tables with parameter descriptions of fence devices.
Note
Certain fence devices have an optional parameter. The parameter allows specifying that a fence-device password is supplied from a script rather than from the parameter. Using the parameter supersedes the parameter, allowing passwords to not be visible in the cluster configuration file (/etc/cluster/cluster.conf).
|
Field
|
Description
|
|
Name
|
A name for the APC device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.1. APC Power Switch
|
Field
|
Description
|
|
Name
|
A name for the Brocade device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.2. Brocade Fabric Switch
|
Field
|
Description
|
|
IP Address
|
The IP address assigned to the PAP console.
|
|
Login
|
The login name used to access the PAP console.
|
|
Password
|
The password used to authenticate the connection to the PAP console.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
|
Domain
|
Domain of the Bull PAP system to power cycle
|
Table B.3. Bull PAP (Platform Administration Processor)
|
Field
|
Description
|
|
Name
|
The name assigned to the DRAC.
|
|
IP Address
|
The IP address assigned to the DRAC.
|
|
Login
|
The login name used to access the DRAC.
|
|
Password
|
The password used to authenticate the connection to the DRAC.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.4. Dell DRAC
|
Field
|
Description
|
|
Name
|
A name for the BladeFrame device connected to the cluster.
|
|
CServer
|
The hostname (and optionally the username in the form of username@hostname) assigned to the device. Refer to the fence_egenera(8) man page.
|
|
ESH Path (optional)
|
The path to the esh command on the cserver (default is /opt/pan- mgr/bin/esh)
|
Table B.5. Egenera SAN Controller
|
Field
|
Description
|
|
Name
|
A name for the GNBD device used to fence the cluster. Note that the GFS server must be accessed via GNBD for cluster node fencing support.
|
|
Server
|
The hostname of each GNBD to disable. For multiple hostnames, separate each hostname with a space.
|
Table B.6. GNBD (Global Network Block Device)
|
Field
|
Description
|
|
Name
|
A name for the server with HP iLO support.
|
|
Hostname
|
The hostname assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.7. HP iLO (Integrated Lights Out)
|
Field
|
Description
|
|
Name
|
A name for the IBM BladeCenter device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.8. IBM Blade Center
|
Field
|
Description
|
|
Name
|
A name for the RSA device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.9. IBM Remote Supervisor Adapter II (RSA II)
|
Field
|
Description
|
|
IP Address
|
The IP address assigned to the IPMI port.
|
|
Login
|
The login name of a user capable of issuing power on/off commands to the given IPMI port.
|
|
Password
|
The password used to authenticate the connection to the IPMI port.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
|
Authentication Type
|
none, password, md2, or md5
|
|
Use Lanplus
|
True or 1. If blank, then value is False.
|
Table B.10. IPMI (Intelligent Platform Management Interface) LAN
|
Field
|
Description
|
|
Name
|
A name to assign the Manual fencing agent. Refer to fence_manual(8) for more information.
|
Table B.11. Manual Fencing
Warning
Manual fencing is not supported for production environments.
|
Field
|
Description
|
|
Name
|
A name for the McData device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.12. McData SAN Switch
|
Field
|
Description
|
|
Name
|
A name for the WTI RPS-10 power switch connected to the cluster.
|
|
Device
|
The device the switch is connected to on the controlling host (for example, /dev/ttys2).
|
|
Port
|
The switch outlet number.
|
Table B.13. RPS-10 Power Switch (two-node clusters only)
|
Field
|
Description
|
|
Name
|
A name for the SANBox2 device connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Login
|
The login name used to access the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.14. QLogic SANBox2 Switch
|
Field
|
Description
|
|
Name
|
Name of the node to be fenced. Refer to fence_scsi(8) for more information.
|
Table B.15. SCSI Fencing
|
Field
|
Description
|
|
Name
|
Name of the guest to be fenced.
|
Table B.16. Virtual Machine Fencing
|
Field
|
Description
|
|
Name
|
A name for the Vixel switch connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.17. Vixel SAN Switch
|
Field
|
Description
|
|
Name
|
A name for the WTI power switch connected to the cluster.
|
|
IP Address
|
The IP address assigned to the device.
|
|
Password
|
The password used to authenticate the connection to the device.
|
|
Password Script (optional)
|
The script that supplies a password for access to the fence device. Using this supersedes the parameter.
|
Table B.18. WTI Power Switch