[libvirt] [PATCHv6 5/7] Enable the blkdeviotune command in virsh

Eric Blake eblake at redhat.com
Wed Nov 23 21:44:47 UTC 2011


From: Lei Li <lilei at linux.vnet.ibm.com>

Support virsh command blkdeviotune. Can set or query a block disk
I/O throttle setting.

Signed-off-by: Lei Li <lilei at linux.vnet.ibm.com>
Signed-off-by: Zhi Yong Wu <wuzhy at linux.vnet.ibm.com>
Signed-off-by: Eric Blake <eblake at redhat.com>
---
 tools/virsh.c   |  244 +++++++++++++++++++++++++++++++++++++++++++++++++++++++
 tools/virsh.pod |   30 +++++++
 2 files changed, 274 insertions(+), 0 deletions(-)

diff --git a/tools/virsh.c b/tools/virsh.c
index 50fc98d..ea5a267 100644
--- a/tools/virsh.c
+++ b/tools/virsh.c
@@ -6076,6 +6076,249 @@ cmdNetworkAutostart(vshControl *ctl, const vshCmd *cmd)
 }

 /*
+ * "blkdeviotune" command
+ */
+static const vshCmdInfo info_blkdeviotune[] = {
+    {"help", N_("Set or query a block device I/O tuning parameters.")},
+    {"desc", N_("Set or query disk I/O parameters such as block throttling.")},
+    {NULL, NULL}
+};
+
+static const vshCmdOptDef opts_blkdeviotune[] = {
+    {"domain", VSH_OT_DATA, VSH_OFLAG_REQ, N_("domain name, id or uuid")},
+    {"device", VSH_OT_DATA, VSH_OFLAG_REQ, N_("block device")},
+    {"total_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("total throughput limit in bytes per second")},
+    {"read_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("read throughput limit in bytes per second")},
+    {"write_bytes_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("write throughput limit in bytes per second")},
+    {"total_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("total I/O operations limit per second")},
+    {"read_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("read I/O operations limit per second")},
+    {"write_iops_sec", VSH_OT_INT, VSH_OFLAG_NONE,
+     N_("write I/O operations limit per second")},
+    {"config", VSH_OT_BOOL, 0, N_("affect next boot")},
+    {"live", VSH_OT_BOOL, 0, N_("affect running domain")},
+    {"current", VSH_OT_BOOL, 0, N_("affect current domain")},
+    {NULL, 0, 0, NULL}
+};
+
+static bool
+cmdBlkdeviotune(vshControl *ctl, const vshCmd *cmd)
+{
+    virDomainPtr dom = NULL;
+    const char *name, *disk;
+    unsigned long long total_bytes_sec = 0, read_bytes_sec = 0, write_bytes_sec = 0;
+    unsigned long long total_iops_sec = 0, read_iops_sec = 0, write_iops_sec = 0;
+    int nparams = 0;
+    virTypedParameterPtr params = NULL, temp = NULL;
+    unsigned int flags = 0, i = 0;
+    int rv = 0;
+    int current = vshCommandOptBool(cmd, "current");
+    int config = vshCommandOptBool(cmd, "config");
+    int live = vshCommandOptBool(cmd, "live");
+    bool ret = false;
+
+    if (current) {
+        if (live || config) {
+            vshError(ctl, "%s", _("--current must be specified exclusively"));
+            return false;
+        }
+        flags = VIR_DOMAIN_AFFECT_CURRENT;
+    } else {
+        if (config)
+            flags |= VIR_DOMAIN_AFFECT_CONFIG;
+        if (live)
+            flags |= VIR_DOMAIN_AFFECT_LIVE;
+    }
+
+    if (!vshConnectionUsability(ctl, ctl->conn))
+        goto cleanup;
+
+    if (!(dom = vshCommandOptDomain(ctl, cmd, &name)))
+        goto cleanup;
+
+    if (vshCommandOptString(cmd, "device", &disk) < 0)
+        goto cleanup;
+
+    if ((rv = vshCommandOptULongLong(cmd, "total_bytes_sec", &total_bytes_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if ((rv = vshCommandOptULongLong(cmd, "read_bytes_sec", &read_bytes_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if ((rv = vshCommandOptULongLong(cmd, "write_bytes_sec", &write_bytes_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if ((rv = vshCommandOptULongLong(cmd, "total_iops_sec", &total_iops_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if ((rv = vshCommandOptULongLong(cmd, "read_iops_sec", &read_iops_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if ((rv = vshCommandOptULongLong(cmd, "write_iops_sec", &write_iops_sec)) < 0) {
+        vshError(ctl, "%s",
+                 _("Unable to parse integer parameter"));
+        goto cleanup;
+    } else if (rv > 0) {
+        nparams++;
+    }
+
+    if (nparams == 0) {
+
+        if ((virDomainGetBlockIoTune(dom, NULL, NULL, &nparams, flags)) != 0) {
+            vshError(ctl, "%s",
+                     _("Unable to get number of block I/O throttle parameters"));
+            goto cleanup;
+        }
+
+        if (nparams == 0) {
+            ret = true;
+            goto cleanup;
+        }
+
+        params = vshCalloc(ctl, nparams, sizeof(*params));
+
+        if ((virDomainGetBlockIoTune(dom, disk, params, &nparams, flags)) != 0) {
+            vshError(ctl, "%s",
+                     _("Unable to get block I/O throttle parameters"));
+            goto cleanup;
+        }
+
+        for (i = 0; i < nparams; i++) {
+            switch(params[i].type) {
+                case VIR_TYPED_PARAM_INT:
+                    vshPrint(ctl, "%-15s: %d\n", params[i].field,
+                             params[i].value.i);
+                    break;
+                case VIR_TYPED_PARAM_UINT:
+                    vshPrint(ctl, "%-15s: %u\n", params[i].field,
+                             params[i].value.ui);
+                    break;
+                case VIR_TYPED_PARAM_LLONG:
+                    vshPrint(ctl, "%-15s: %lld\n", params[i].field,
+                             params[i].value.l);
+                    break;
+                case VIR_TYPED_PARAM_ULLONG:
+                    vshPrint(ctl, "%-15s: %llu\n", params[i].field,
+                             params[i].value.ul);
+                    break;
+                case VIR_TYPED_PARAM_DOUBLE:
+                    vshPrint(ctl, "%-15s: %f\n", params[i].field,
+                             params[i].value.d);
+                    break;
+                case VIR_TYPED_PARAM_BOOLEAN:
+                    vshPrint(ctl, "%-15s: %d\n", params[i].field,
+                             params[i].value.b);
+                    break;
+                default:
+                    vshPrint(ctl, "unimplemented block I/O throttle parameter type\n");
+            }
+        }
+
+        virDomainFree(dom);
+        return true;
+    } else {
+        /* Set the block I/O throttle, match by opt since parameters can be 0 */
+        params = vshCalloc(ctl, nparams, sizeof(*params));
+        i = 0;
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "total_bytes_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_TOTAL_BYTES_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = total_bytes_sec;
+            i++;
+        }
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "read_bytes_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_READ_BYTES_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = read_bytes_sec;
+            i++;
+        }
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "write_bytes_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_WRITE_BYTES_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = write_bytes_sec;
+            i++;
+        }
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "total_iops_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_TOTAL_IOPS_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = total_iops_sec;
+            i++;
+        }
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "read_iops_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_READ_IOPS_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = read_iops_sec;
+            i++;
+        }
+
+        if ((i < nparams) && (vshCommandOptBool(cmd, "write_iops_sec"))) {
+            temp = &params[i];
+            temp->type = VIR_TYPED_PARAM_ULLONG;
+            strncpy(temp->field, VIR_DOMAIN_BLOCK_IOTUNE_WRITE_IOPS_SEC,
+                    sizeof(temp->field));
+            temp->value.ul = write_iops_sec;
+        }
+
+        if ((virDomainSetBlockIoTune(dom, disk, params, nparams, flags)) < 0) {
+            vshError(ctl, "%s",
+                     _("Unable to change block I/O throttle"));
+            goto cleanup;
+        }
+    }
+
+    ret = true;
+
+cleanup:
+    VIR_FREE(params);
+    virDomainFree(dom);
+    return ret;
+}
+
+/*
  * "net-create" command
  */
 static const vshCmdInfo info_network_create[] = {
@@ -14689,6 +14932,7 @@ static const vshCmdDef domManagementCmds[] = {
     {"attach-interface", cmdAttachInterface, opts_attach_interface,
      info_attach_interface, 0},
     {"autostart", cmdAutostart, opts_autostart, info_autostart, 0},
+    {"blkdeviotune", cmdBlkdeviotune, opts_blkdeviotune, info_blkdeviotune, 0},
     {"blkiotune", cmdBlkiotune, opts_blkiotune, info_blkiotune, 0},
     {"blockpull", cmdBlockPull, opts_block_pull, info_block_pull, 0},
     {"blockjob", cmdBlockJob, opts_block_job, info_block_job, 0},
diff --git a/tools/virsh.pod b/tools/virsh.pod
index db872dd..8737cac 100644
--- a/tools/virsh.pod
+++ b/tools/virsh.pod
@@ -572,6 +572,36 @@ operation can be checked with B<blockjob>.
 I<path> specifies fully-qualified path of the disk.
 I<bandwidth> specifies copying bandwidth limit in Mbps.

+=item B<blkdeviotune> I<domain> I<device>
+[[I<--config>] [I<--live>] | [I<--current>]]
+[[I<total_bytes_sec>] | [I<read_bytes_sec>] [I<write_bytes_sec>]]
+[[I<total_iops_sec>] | [I<read_iops_sec>] [I<write_iops_sec>]]
+
+Set or query the block disk io parameters for a block device of I<domain>.
+I<device> specifies a unique target name (<target dev='name'/>) or source
+file (<source file='name'/>) for one of the disk devices attached to
+I<domain> (see also B<domblklist> for listing these names).
+
+If no limit is specified, it will query current I/O limits setting.
+Otherwise, alter the limits with these flags:
+I<--total_bytes_sec> specifies total throughput limit in bytes per second.
+I<--read_bytes_sec> specifies read throughput limit in bytes per second.
+I<--write_bytes_sec> specifies write throughput limit in bytes per second.
+I<--total_iops_sec> specifies total I/O operations limit per second.
+I<--read_iops_sec> specifies read I/O operations limit per second.
+I<--write_iops_sec> specifies write I/O operations limit per second.
+
+When setting any value, all remaining values are reset to unlimited,
+an explicit 0 also clears any limit.  A non-zero value for a given total
+cannot be mixed with non-zero values for read or write.
+
+If I<--live> is specified, affect a running guest.
+If I<--config> is specified, affect the next boot of a persistent guest.
+If I<--current> is specified, affect the current guest state.
+Both I<--live> and I<--current> flags may be given, but I<--current> is
+exclusive. If no flag is specified, behavior is different depending
+on hypervisor.
+
 =item B<blockjob> I<domain> I<path> [I<--abort>] [I<--info>] [I<bandwidth>]

 Manage active block operations.
-- 
1.7.7.3