[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]

Re: [Linux-cluster] fencing issue.



That won't work then since pulling the power cable effectively disables the drac port. You need some out of band controller for that type of fencing to work. I use APC units, others will prefer different units. It's the same problem as with an iLO. Actually, you can get into the same problem if your power controllers and nodes are in different racks and you have a rack level failure.


Regards

Corey

On Wed, Mar 3, 2010 at 11:05 AM, שלום קלמר <sklemer gmail com> wrote:
Hi.
 
I am runnig fence_ipmilan on iDRAC6.
 
Regards
 
Shalom

On Wed, Mar 3, 2010 at 6:22 AM, Rajagopal Swaminathan <raju rajsand gmail com> wrote:
Greetings,

On Tue, Mar 2, 2010 at 10:40 PM, שלום קלמר <sklemer gmail com> wrote:
> Hello.
>
> Everything is working fine. We did some failover tests, all tests passed (
> nic , fiber , reboot ).
>
> The only test which failed was - pulling out power cable from one node.
>


How do you do the fencing? in-band (ILO, RSA, ALOM, DRAC) or
out-of-band (Power fencing)

Regards,

Rajagopal


--
Linux-cluster mailing list
Linux-cluster redhat com
https://www.redhat.com/mailman/listinfo/linux-cluster