[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed



Hi,

On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
Hi all,

I am using RHCS on IBM bladecenter with blade center fencing. I plugged out a blade from blade center chassis slot and was hoping that failover to occur. However when I did so, I get following message -

fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain correct plug status or plug is not available
fenced[10240]: fence "blade1" failed

Is this supported that if I plug out blade from its slot, then failover occur without manual intervention? If so, which fencing must I use?

You can use option missing_as_off (or --missing-as-off at command line) which returns off even in a case when blade does not exists.

m,