[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]

Re: [Linux-cluster] Plugged out blade from bladecenter chassis - fence_bladecenter failed



Hi Marek,

Can we give this option in cluster.conf file for bladecenter fencing device or method

For IPMI, fencing is there similar option?


On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac <mgrac redhat com> wrote:
Hi,


On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
Hi all,

I am using RHCS on IBM bladecenter with blade center fencing. I plugged out a blade from blade center chassis slot and was hoping that failover to occur. However when I did so, I get following message -

fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain correct plug status or plug is not available
fenced[10240]: fence "blade1" failed

Is this supported that if I plug out blade from its slot, then failover occur without manual intervention? If so, which fencing must I use?

You can use option missing_as_off (or --missing-as-off at command line) which returns off even in a case when blade does not exists.

m,
--
Linux-cluster mailing list
Linux-cluster redhat com
https://www.redhat.com/mailman/listinfo/linux-cluster


[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Thread Index] [Date Index] [Author Index]