[Linux-cluster] fencing issue - with attach logs&conf

Georgi Stanojevski glisha at gmail.com
Tue Mar 2 23:15:12 UTC 2010


On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <sklemer at gmail.com> wrote:

>
> The only test which failed was - pulling out power cable from one node.
>
> The other system try in loop fencing the failed node & services not
> relocated.
>
>
>
As I understand this is by design.

When you pull out the power cables you shutdown the fencing device on that
node and the remaining node can't successfully fence it.

The nodes should have redundant power supplies, to avoid single point of
failure.

-- 
Glisha